Operational Non-Contact Diagnostics of Induction Machine Based on Stray Electromagnetic Field Cover Image

Operational Non-Contact Diagnostics of Induction Machine Based on Stray Electromagnetic Field
Operational Non-Contact Diagnostics of Induction Machine Based on Stray Electromagnetic Field

Author(s): Petr Bernat, Petr Kacor
Subject(s): Energy and Environmental Studies, Methodology and research technology
Published by: Žilinská univerzita v Žilině
Keywords: Induction machine; asynchronous motor; functional testing; technical diagnostics; frequency spectrum; current spectrum; stray electromagnetic field; leakage electromagnetic field;

Summary/Abstract: Paper deals with one new method of testing and operational diagnostics of induction machines using a stray electromagnetic field. This leakage field on the surface or on surroundings of machine frame is the carrier for diagnostic information and we can make simultaneous comparisons of utility, advantages and disadvantages of the existing and most common methods of diagnostics performed using the measurement of the machine supply current. This method is patented as Czech Patent CZ 303 470, UPV 2012.

  • Issue Year: 17/2015
  • Issue No: 1A
  • Page Range: 89-94
  • Page Count: 6
  • Language: English